This content is licensed under Creative Commons Attribution/Share-Alike License 3.0 (Unported). That means you may freely redistribute or modify this content under the same license conditions and must attribute the original author by placing a hyperlink from your site to this work https://planetcalc.com/8189/. Also, please do not modify any references to the original work (if any) contained in this content.

Pipe Wall Thickness

Barlow´s Formula is used to calculate the pipe pressure considering its diameter, wall thickness, and hoop stress (in the pipe material). Thus, it can be used to calculate whichever one of those parameters as a function of the other three.
In addition to some other simplifications, an important theoretical assumption made for the use of Barlow´s formula is that the pipe wall behaves like a membrane (or thin wall pipe), meaning the hoop stress in the pipe wall is distributed uniformly in all its thickness. There are no moments of any type within the pipe wall.One parameter to ensure that the membrane behavior happens in the pipe wall is the diameter over thickness ratio (D/t) to be bigger or equal to 20 1 2, although some authors consider 16 3.
However, the decision of using or not of the formula is usually not based on its section geometry (D/t ratio), but on the service of the pipe, considering the type of fluid, industry, and physical conditions, like for instance, the ASME (American Association of Mechanical Engineers) does.

Pipe B3.jpg

P=\frac{2St}{D}

  • P: Pipe pressure
  • S: Hoop stress
  • t: Pipe wall thickness
  • D: Outside diameter

PLANETCALC, Calculations using Barlow's formula

Calculations using Barlow's formula

Digits after the decimal point: 3
calculated t, (in)
 
calculated S, (psi)
 
calculated D, (in)
 
calculated P, (in)
 

Following that service criteria, the ASME B31.4 code (Pipeline Transportation Systems for Liquids and Slurries) applies the formula in this manner:

t=\frac{PD}{2S}+A

  • A: Allowance for threading, grooving, corrosion

PLANETCALC, Wall Thickness by Barlow's Formula as applied by ASME B31.4

Wall Thickness by Barlow's Formula as applied by ASME B31.4

Digits after the decimal point: 3
Pipe wall thickness, (in)
 

ASME B31.8 code (Gas Transmission and Distribution Piping Systems) applies it in this manner:

P=\frac{2St}{D}FET

and to calculate the minimum wall thickness including an allowance:

P=\frac{2S(t-A)}{D}FET

it should be expressed like this:

t=\frac{PD}{2SFET}+A

  • F: Design Factor
  • E: Longitudinal Joint Factor
  • T: Temperature Derating Factor
  • A: Allowance for threading, grooving, corrosion

PLANETCALC, Pipe Pressure by Barlow's Formula as applied by ASME B31.8

Pipe Pressure by Barlow's Formula as applied by ASME B31.8

Digits after the decimal point: 3
calculated P (psi)
 
calculated t (in)
 

ASME B31.9 code (Building Services Piping) applies it in this manner:

t=\frac{PD}{2SE}+A

  • E: Longitudinal Joint Factor
  • A: Allowance for threading, grooving, corrosion

PLANETCALC, Pipe wall thickness by Barlow's formula as Applied by ASME B31.9

Pipe wall thickness by Barlow's formula as Applied by ASME B31.9

Digits after the decimal point: 3
Pipe wall thickness, (in)
 

On the other hand, as opposed to the thin wall assumption or membrane theory, there is the curved plate or thick wall pipe formulas derived from Lame´s theory whose use is more complicated, sometimes with iterations, and requires a careful approach like, for instance, in ASME B 31.1 code (Power Piping), ASME B 31.3 code (Process Piping), and ASME B 31.5 (Refrigeration Piping and Heat Transfer Components).